Uso del programa de configuración del sistema
155
Comando
NetFn
Código
IPMI 2.0 BMC
Get BT Interface Capabilities
Aplic
0x36h
M
No
Get System GUID
Aplic
0x37h
M
Sí
Set System Info Parameters
Aplic
0x58h
O
Sí
Get System Info Parameters
Aplic
0x59h
O
Sí
Get Channel Authentication Capabilities
Aplic
0x38h
O
Sí
Get Session Challenge
Aplic
0x59h
O
Sí
Activate Session Command
Aplic
0x3Ah
O
Sí
Set Session Privilege Level Command
Aplic
0x3Bh
O
Sí
Close Session
Aplic
0x3Ch
O
Sí
Get Session Information
Aplic
0x3Dh
O
Sí
Get Authentication Code Command
Aplic
0x3Fh
O
Sí
Set Channel Access Commands
Aplic
0x40h
O
Sí
Get Channel Access Commands
Aplic
0x41h
O
Sí
Get Channel Info Command
Aplic
0x42h
O
Sí
Set User Access Commands
Aplic
0x43h
O
Sí
Get User Access Commands
Aplic
0x44h
O
Sí
Set User Name Commands
Aplic
0x45h
O
Sí
Get User Name Commands
Aplic
0x46h
O
Sí
Set User Password Commands
Aplic
0x47h
O
Sí
Active Payload Command
Aplic
0x48h
O
Sí
Deactivate Payload Command
Aplic
0x49h
O
Sí
Get Payload Activation Status
Aplic
0x4Ah
O
Sí
Get Payload Instance Info Command
Aplic
0x4Bh
O
Sí
Set User Payload Access
Aplic
0x4Ch
O
Sí
Get User Payload Access
Aplic
0x4Dh
O
Sí
Get Channel Payload Support
Aplic
0x4Eh
O
Sí
Get Channel Payload Version
Aplic
0x4Fh
O
Sí
Tabla 2-4. Comandos de mensajes y dispositivos de BMC (NetFn: 0x06H) (continuación)