Tabla 4-16, Descripciones de campos de comandos switchshow -30, Descripciones de campos de comandos switchshow4-30 – Dell PowerVault 51F (8P Fibre Channel Switch) Manual del usuario
Página 94

4-30
Guía de instalación y solución de problemas del interruptor de canal de fibra de 8 puertos Dell PowerVault 51F
interruptor:admin> switchShow
switchName: open146
switchType:
3.1
switchState: Online
switchRole: Principal
switchDomain: 1
switchId: fffc41
switchWwn: 10:00:00:60:69:00:04:64
port 0: sw Online FL-Port 1 private, 1 phantom
port 1: -- No_Module G-Port
port 2: sw No_Light G-Port
port 3: sw Online FL-Port 1 private, 1 phantom
port 4: -- No_Module
port 5: sw Online E-Port 10:00:00:60:69:00:00:12 "sw1" (upstream)
port 6: sw No_Light
port 7: sw No_Light
port 8: sw No_Light
port 9: sw Online E-Port 10:00:00:60:69:00:01:b4 "sw3" (downstream)
port 10: sw No_Light
port 11: sw No_Light
port 12: sw No_Light
port 13: sw No_Light
port 14: sw No_Light
port 15: sw No_Light
value = 16 = 0x10
Tabla 4-16. Descripciones de campos de comandos
switchShow
Campo
Descripción
switchName
El nombre del interruptor.
switchType
El número del modelo y el nivel de revisión de la placa base. El
número del modelo es el siguiente:
1 = PowerVault 50F
2 = Reservado
3 = PowerVault 51F
switchState
El estado de este interruptor: en línea, fuera de línea, pro-
bando o defectuoso.
switchRole
Hay tres posibilidades para switchRole entre las cuales se
cuentan:
•
Principle (Principal) — El interruptor principal según se
define en FC-SW
•
Subordinate (Subordinado) — Este interruptor se activa y
es un interruptor subordinado
•
Disabled (Desactivado)— El interruptor se desactiva.