Cutmaster 35 y 40 mm – Tweco CutMaster 35mm 40mm Manual del usuario
Página 79

CUTMASTER 35 Y 40 mm
Manual 0-5118
A-7
ANEXOS
Art # A-08534
Art # A-08534
5
5
4
4
3
3
2
2
1
1
D
D
C
C
B
B
A
A
+12VDC
+12VDC
+12VDC
+12VDC
+12VDC
24VAC
+12VDC
+5VDC
+12VDC
+12VDC
+12VDC
+12VDC
DWG No:
Sheet
of
Supersedes
Scale
Create Date:
Drawn:
Reference
Date
By
Change Description
Rev
Information Proprietary to THERMADYNE INDUSTRIES
Not For Release, Reproduction, or Distribution without Written Consent.
NOTE: UNLESS OTHERWISE SPECIFIED -
1. RESISTOR VALUES ARE EXPRESSED IN OHMS, 1/4W 5%.
2. CAPACITOR VALUES ARE EXPRESSED IN MICROFARADS (uF).
Chk: App:
TITLE:
Last Modified:
SCHEMATIC,
NONE
42X1321
Tuesday, July 01, 2008
1
1
82 Benning Street
West Lebanon, NH
03784
CutMaster 35mm/40mm 400VAC Systems
07:56:12
THERMADYNE
ECO-B1014
MNC
07/01/08
<DRAWN>
AA
DWG No:
Sheet
of
Supersedes
Scale
Create Date:
Drawn:
Reference
Date
By
Change Description
Rev
Information Proprietary to THERMADYNE INDUSTRIES
Not For Release, Reproduction, or Distribution without Written Consent.
NOTE: UNLESS OTHERWISE SPECIFIED -
1. RESISTOR VALUES ARE EXPRESSED IN OHMS, 1/4W 5%.
2. CAPACITOR VALUES ARE EXPRESSED IN MICROFARADS (uF).
Chk: App:
TITLE:
Last Modified:
SCHEMATIC,
NONE
42X1321
Tuesday, July 01, 2008
1
1
82 Benning Street
West Lebanon, NH
03784
CutMaster 35mm/40mm 400VAC Systems
07:56:12
THERMADYNE
ECO-B1014
MNC
07/01/08
<DRAWN>
AA
DWG No:
Sheet
of
Supersedes
Scale
Create Date:
Drawn:
Reference
Date
By
Change Description
Rev
Information Proprietary to THERMADYNE INDUSTRIES
Not For Release, Reproduction, or Distribution without Written Consent.
NOTE: UNLESS OTHERWISE SPECIFIED -
1. RESISTOR VALUES ARE EXPRESSED IN OHMS, 1/4W 5%.
2. CAPACITOR VALUES ARE EXPRESSED IN MICROFARADS (uF).
Chk: App:
TITLE:
Last Modified:
SCHEMATIC,
NONE
42X1321
Tuesday, July 01, 2008
1
1
82 Benning Street
West Lebanon, NH
03784
CutMaster 35mm/40mm 400VAC Systems
07:56:12
THERMADYNE
ECO-B1014
MNC
07/01/08
<DRAWN>
AA
_
19X2369 / CAT# 9-0107
OVER PRESSURE
INTERNAL ERROR
SHORTED TORCH
CONSUMABLES MISSING
START ERROR
PARTS IN PLACE
INPUT POWER
UNDER PRESSURE
ERROR IND FAULT
PCB3
INRUSH
RESISTORS
LATCH
SET
RUN
RAR
MAX
90
85
80
75
70
65
MIN
TP1
TP2
TP3
TP4
TP5
TP6
TP7
LOGIC PCB
GND
+12 VDC
+5 VDC
3.3 VDC
0.v - 5.0 VDC / 0-100PSI
1.8 VDC
CURRENT DEMAND
TEST POINTS
FAN
TEMP
CIRCUIT
3.3VDC
TXD
RXD
Q2
D
SERIAL PORT
80
81
82
83
E64
E35
78
79
-
+
*CM 35mm C7 & C10
not installed
ATC CONNECTOR
GND1
GND2
+12V1
48V1
I_DMD_1
TIP_SEN
COMMON
COMMON
+12 VDC SUPPLY
+48 VDC SUPPLY
CURRENT DEMAND
TIP DRAG SENSE
TEST POINTS
CM 40mm ONLY
J2
_
J1
/4
00
J2 PINOUT
1
8
9
3
4
7
7A
8
11
12
14
OK-TO-MOVE
L1
L2
L3
L4
T1
T2
T3
T4
/PIP
PCB1
+
+
+
+
Q1
24VAC RET
5
PRIMARY
AC INPUT
400VAC 3PH
6
/START
/SOLENOID
24VAC RETURN
24VAC SUPPLY
CM 35mm 19X2371 / CAT# 9-0108
CM 40mm 19X2416 / CAT# 9-0125
MAIN PCB
7
/OVERTEMP
TEMP
CIRCUIT
PRESSURE
TRANSDUCER
AIR
INLET
FILTER
REGULATOR
SOLENOID
VALVE
ATC
GAS CONTROL
0-100PSI / 0-4.5VDC
/INRUSH
/OVERTEMP
D3
D1
L1
L2
L3
GND
(5A @ 250VAC / 30VDC)
C
D
B
A
1TORCH
_
AUTOMATION
TORCH SOLENOID
Q2
_
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
29
34
35
36
37
38
39
-V_OUT_SIGNAL
/TIP_VOLTS
/TIP_SENSE
/400V_IN
N/A
CUR_SET
/RAR (RAPID AUTO RESTART)
/INRUSH
/W1_ON
SHDN
/TORCH_SOLENOID
/SOLENOID_ON
/OK_TO_MOVE
/FAN_ON
/LATCH_ACTIVE
/TORCH_SWITCH
/PIP
AC_ON
CSR
/TORCH_SOLENOID_DETECT
/OVERTEMP
V_IN
+12VDC
+12VDC
COMMON
COMMON
MAIN_PCB_ID
460_IN
+3.3VDC
TXD
RXD
COMMON
D
M-L
M-L
M-L
L-M
L-M
L-M
L-M
L-M
L-M
L-M
L-M
L-M
L-M
L-M
M-L
M-L
M-L
M-L
M-L
M-L
M-L
M-L
M-L
M-L
M-L
M-L
M-L
L-M
M-L
M-L
L-M
M-L
40 PIN RIBBON CABLE SIGNALS
B
CM 35mm 19X2478 / CAT# 9-0192
CM 40mm 19X2545 / CAT# 9-0202
A
PCB5
CM 35mm 40 AMP PCB
19X2417 / CAT# 9-0194
CM 40mm 50 AMP PCB
19X2417 / CAT# 9-0203
PCB2
Q1
FAN
/FAN
FAN
/FAN
D2
D1
C
D
CAPACITOR PCB
1 /OVERTEMP
2 /FAN_ON
3 /CSR
4 CUR_SET
5 MAIN_PCB_ID
6 COMMON
SYNC
}
OK-TO-MOVE
OK TO MOVE
}
}
PCB4
AUTOMATION
INTERFACE PCB
19X2479 / CAT# 9-8311
FULL FEATURED AUTOMATION INTERFACE PCB OPTION
BASIC CNC INTERFACE OPTION
(+)
}
To configure DIVIDED ARC VOLTS signal output
Jumper pins 1 & 2 for ARC VOLTS / 50
Jumper pins 2 & 3 for ARC VOLTS / 16
K1
To -V OUT 1
on PCB1
}
/START / STOP
*
*
}
DIVIDED ARC VOLTS
/START / STOP
(+)
(-) (W/ 100K IN SERIES (2))
(-)
*
ARC VOLTS
SYNC
1
2
3
4
1
2
3
4
EMI FILTER
CE UNITS
ONLY
K3
K3
40A_AC2
40A_AC2
+
C12-13
+
C12-13
NTC
NTC
J4
J4
1 2 3 4 5 6 7 8 9 10
80
80
SEC1
SEC1
K1
K1
MTH7
MTH7
SEC1
SEC1
TP8
TP8
J2
J2
2
3
4
5
6
7
8
9
10
11
12
13
14
1
SW1
SW1
1
3
2
4
W1
W1
J1
J1
1
2
3
4
5
6
7
8
J12
J12
1
2
3
PMTH1
PMTH1
MAX
MAX
J1
J1
1
2
3
4
5
6
7
8
TS1
TS1
PMTH2
PMTH2
K10
K10
J14
J14
40A_AC3
40A_AC3
AC1
AC1
TIP1
TIP1
MOT2
MOT2 +
-
MTH4
MTH4
SEC2
SEC2
85
85
SEC2
SEC2
J3
J3
3
2
1
MIN
MIN
1
2
3
4
5
6
7
8
J11
J11
1 2
AC3
AC3
TP3
TP3
WORK1
WORK1
TP4
TP4
+
C16-17
+
C16-17
D1
D1
J3
J3
1 2 3
L1
L1
D78 CSR
D78 CSR
90
90
AC2
AC2
MTH8
MTH8
SOL 1
SOL 1
J1
J1
1
2
40A_AC1
40A_AC1
80A_AC1
80A_AC1
MOT1
MOT1
+
-
J1
J1
1
2
3
4
5
J3
J3
1 2
D59 PCR
D59 PCR
PMTH3
PMTH3
PRI 2
PRI 2
1 2 3
MOT3
MOT3 +
-
OVERTEMP
OVERTEMP
J5
J5
1
2
3
Q5
PILOT IGBT
Q5
PILOT IGBT
PIP SWITCH
PIP SWITCH
E1
E1
J1
J1
1
2
3
80A_AC2
80A_AC2
PRI 2
PRI 2
75
75
+
C3,C4,C7,C8*
+
C3,C4,C7,C8*
PMTH1
PMTH1
CHOKE1
CHOKE1
J13
J13
1 2 3 4 5 6
TP5
TP5
J2
J2
1
2
PRI 1
PRI 1
Current Control
Current Control
PRI 4
PRI 4
AC1
AC1
-V OUT 1
-V OUT 1
J4
J4
1
2
3
4
5
PMTH4
PMTH4
GAS
GAS
TP1
TP1
65
65
PRI 3
PRI 3
P10
P10
1
2
3
4
5
6
7
8
+
C5,C6,C9,C10*
+
C5,C6,C9,C10*
K4
K4
J2
J2
2
3
4
5
6
7
8
9
10
11
12
13
14
1
+OUT_1
+OUT_1
L2
L2
MTH6
MTH6
AC3
AC3
T1
T1
J6
J6
1
2
PRI 4
PRI 4
NTC
NTC
J9
J9
TP2
TP2
MTH2
MTH2
70
70
J7
J7
1
2
PMTH4
PMTH4
TORCH SWITCH
TORCH SWITCH
J9
J9
1
2
3
4
5
6
7
PMTH2
PMTH2
PRI 4
PRI 4
WORK
WORK
PRI 1
PRI 1
J2
J2
1
2
W1
W1
DC
DC
MTH1
MTH1
P10
P10
1
2
3
4
5
6
7
8
PMTH3
PMTH3
AC
AC
PRI 3
PRI 3
J10
J10
3
5
6
7
8
1
2
4
80A_AC3
80A_AC3
T2
T2
K3,K4
K3,K4
ERROR
ERROR
AC2
AC2
CHOKE1
CHOKE1
PRI 3
PRI 3
ELECTRODE1
ELECTRODE1