8 cableado del circuito principal – Yaskawa CIMR-AU 200V Manual del usuario
Página 155

Modelo de
variador
Terminal
Calibre recomendado
AWG, kcmil
Rango de cable
AWG, kcmil
Tamaño de
los
tornillos
Torque de ajuste
N·m (lb.in.)
4A0139
R/L1, S/L2, T/L3
3/0
1/0 a 4/0
M10
18 a 23
(159 a 204)
U/T1, V/T2, W/T3
2/0
1/0 a 4/0
⊖, ⊕1
–
1/0 a 4/0
⊕3
–
3 a 4/0
4
4
4A0165
R/L1, S/L2, T/L3
4/0
3/0 a 4/0
M10
18 a 23
(159 a 204)
U/T1, V/T2, W/T3
4/0
3/0 a 4/0
⊖, ⊕1
–
1 a 4/0
⊕3
–
1/0 a 4/0
4
4 a 2
4A0208
R/L1, S/L2, T/L3
300
2 a 300
M10
18 a 23
(159 a 204)
U/T1, V/T2, W/T3
300
2 a 300
⊖, ⊕1
–
1 a 250
⊕3
–
3 a 3/0
4
4 a 300
4A0250
R/L1, S/L2, T/L3
400
1 a 600
M10
18 a 23
(159 a 204)
U/T1, V/T2, W/T3
400
1/0 a 600
⊖, ⊕1
–
3/0 a 600
⊕3
–
1 a 325
2
2 a 350
4A0296
R/L1, S/L2, T/L3
500
2/0 a 600
M12
32 a 40
(283 a 354)
U/T1, V/T2, W/T3
500
2/0 a 600
⊖, ⊕1
–
3/0 a 600
⊕3
–
1 a 325
M10
18 a 23
(159 a 204)
2
2 a 350
M12
32 a 40
(283 a 354)
4A0362
R/L1, S/L2, T/L3
4/0 × 2P
3/0 a 600
M12
32 a 40
(283 a 354)
U/T1, V/T2, W/T3
4/0 × 2P
3/0 a 600
⊖, ⊕1
–
4/0 a 600
⊕3
–
3/0 a 600
M10
18 a 23
(159 a 204)
1
1 a 350
M12
32 a 40
(283 a 354)
4A0414
R/L1, S/L2, T/L3
300 × 2P
4/0 a 300
M12
32 a 40
(283 a 354)
U/T1, V/T2, W/T3
300 × 2P
4/0 a 300
⊖, ⊕1
–
3/0 a 300
⊕3
–
3/0 a 300
1
1 a 3/0
4A0515
R/L1, S/L2, T/L3
3/0 × 4P
3/0 a 300
M12
32 a 40
(283 a 354)
U/T1, V/T2, W/T3
4/0 × 4P
3/0 a 300
⊖, ⊕1
–
1/0 a 300
⊕3
–
1/0 a 300
1/0
1/0 a 300
4A0675
R/L1, S/L2, T/L3
300 × 4P
4/0 a 300
M12
32 a 40
(283 a 354)
U/T1, V/T2, W/T3
300 × 4P
4/0 a 300
⊖, ⊕1
–
1/0 a 300
⊕3
–
1/0 a 300
2/0
2/0 a 300
4A0930
R/L1, S/L2, T/L3, R1/L11, S1/L21,
T1/L31
4/0 × 4P×2
3/0 a 300
M12
32 a 40
(283 a 354)
U/T1, V/T2, W/T3
4/0 × 4P×2
3/0 a 300
⊖, ⊕1
–
4/0 a 300
⊕3
–
4/0 a 300
3/0
3/0 a 250
3.8 Cableado del circuito principal
YASKAWA ELECTRIC SISP C710616 41E Variador de CA YASKAWA A1000 Manual Técnico
155
3
Instalación eléctrica